This paper is only available as a PDF. To read, Please Download here.
A number of microdilution and agar-replicating systems are currently available for
the rapid, accurate identification of common bacterial pathogens. These systems can
be highly automated for large clinical laboratories or used manually for small laboratories.
To read this article in full you will need to make a payment
Purchase one-time access:
Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online accessOne-time access price info
- For academic or personal research use, select 'Academic and Personal'
- For corporate R&D use, select 'Corporate R&D Professionals'
Subscribers receive full online access to your subscription and archive of back issues up to and including 2002.
Content published before 2002 is available via pay-per-view purchase only.
Subscribe:
Subscribe to Clinics in Laboratory MedicineAlready a print subscriber? Claim online access
Already an online subscriber? Sign in
Register: Create an account
Institutional Access: Sign in to ScienceDirect
References
- Identification of Enterobacteriaceae in frozen microdilution trays prepared by micromedia systems.J. Clin. Microbiol. 1979; 10: 492-496
- Comparison of enteric identification systems.Health Lab. Sei. 1977; 14: 5-10
- Evaluation of the Repliscan system for identification of Enterobacteriaceae.J. Clin. Microbiol. 1978; 8: 695-699
- Evaluation of the Auto Scan-3, a device for reading microdilution trays.J. Clin. Microbiol. 1983; 18: 1292-1295
- Preliminary evaluation of the Auto Scan-3, an instrument for automated reading and interpretation of microdilution trays: Identification of aerobic gram-negative bacilli.J. Clin. Microbiol. 1981; 14: 326-328
- Comparison of the Auto Microbic System with API, Enterotube, Micro-ID, Micro-Media Systems, and conventional methods for identification of Enterobacteriaceae.J. Clin. Microbiol. 1980; 12: 659-662
- Evaluation of Micro-Media Quad panels for identification of the Enterobacteriaceae.J. Clin. Microbiol. 1979; 10: 515-518
- Evaluation of the Microscan Urinary Combo Panel and API 20E System for identification of glucose-nonfermenting gram-negative bacilli isolated from clinical veterinary materials.J. Clin. Microbiol. 1983; 17: 139-142
- Evaluation of the Sensititre system for identification of Enterobacteriaceae.J. Clin. Microbiol. 1983; 17: 647-654
- Evaluation of the Repliscan II system for identification of Enterobacteriaceae.J. Clin. Microbiol. 1981; 14: 408-410
- Evaluation of the Auto Scan-3 and Sceptor systems for Enterobacteriaceae identification.J. Clin. Microbiol. 1983; 17: 807-813
- Evaluation of the Repliscan system for Enterobacteriaceae identification.J. Clin. Microbiol. 1981; 13: 58-61
Article info
Identification
Copyright
© 1985 Elsevier Inc. Published by Elsevier Inc. All rights reserved.