Keywords
Purchase one-time access:
Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online accessOne-time access price info
- For academic or personal research use, select 'Academic and Personal'
- For corporate R&D use, select 'Corporate R&D Professionals'
Subscribers receive full online access to your subscription and archive of back issues up to and including 2002.
Content published before 2002 is available via pay-per-view purchase only.
Subscribe:
Subscribe to Clinics in Laboratory MedicineReferences
- The mass-spectra of chemical elements.The London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science. 1920; 39: 611-625
- The discharge of electricity through gases.Charles Scribner's Sons, New York1898
- Rays of positive electricity and their application to chemical analysis.Longmans Green, London1913
- On the appearance of helium and neon in vacuum tubes.Science. 1913; 37: 360-364
- Some reminiscences of mass spectrometry and the Manhattan Project.J Chem Educ. 1989; 66: 385-388
- The history and heritage of scientific and technological information systems: Proceedings of the 2002 conference.Information Today, Inc, Medford (NJ)2004
Drew CM, Smith SR. ASTM E-14 Meeting on Mass Spectrometry. San Francisco, May 1955. p. 36.
- Fourier transform ion cyclotron resonance spectroscopy.Chem Phys Lett. 1974; 25: 282-283
- Liquid chromatograph-mass spectrometer for analysis of nonvolatile samples.Anal Chem. 1980; 52: 1636-1641
- Subpicogram detection system for gas phase analysis based upon atmospheric pressure ionization (API) mass spectrometry.Anal Chem. 1974; 46: 706-710
- Electrospray ion source. Another variation on the free-jet theme.J Phys Chem. 1984; 88: 4451-4459
- Selected ion fragmentation with a tandem quadrupole mass spectrometer.J Am Chem Soc. 1978; 100: 2274-2275
- Tandem mass spectrometry: a new method for acylcarnitine profiling with potential for neonatal screening for inborn errors of metabolism.J Inherit Metab Dis. 1990; 13: 321-324
- Mass spectrometry: an introduction.6th edition. Wiley-VCH, Weinheim, Germany2012
- Instability of electrified liquid surfaces.Phys Rev. 1917; 10: 1-7
- Atmospheric pressure ionization mass spectrometry. Corona discharge ion source for use in a liquid chromatograph-mass spectrometer-computer analytical system.Anal Chem. 1975; 47: 2369-2372
Short LC, SS, Syage JA. APPI: the second source for LC-MS. 2008. Available at: http://www.chromatographyonline.com/appi-second-source-lc-ms. Accessed March 24, 2016.
- Atmospheric pressure photoionization. 1. General properties for LC/MS.Anal Chem. 2004; 76: 2842-2851
- LC-MS/MS in the clinical laboratory—where to from here?.Clin Biochem Rev. 2011; 32: 5-31
- Exhaled breath condensate: a comprehensive update.Clin Chem Lab Med. 2013; 51: 1343-1361
- Updates in immunoassays: introduction.Clin Lab Sci. 2012; 25: 170-172
- Handbook of immunodiffusion and immunoelectrophoresis. With appendices by three other authorities, and an equipment section.Ann Arbor Science Publishers, Ann Arbor (MI)1968
- Immunoassay of endogenous plasma insulin in man.J Clin Invest. 1960; 39: 1157-1175
- Henry's clinical diagnosis and management by laboratory methods.Elsevier, St. Louis (MO)2011
- Clinical laboratory medicine.Lippincott Wiliams & Wilkins, Philadelphia2002
- Position of immunological techniques in screening in clinical toxicology.Clin Chem Lab Med. 2004; 42: 1288-1309
- Use of on-site testing for drugs of abuse.Clin Chem. 2002; 48: 1639-1646
Abuelzein E, Institute for New T. Trends in Immunolabelled and Related Techniques. 2012. Available at: http://www.intechopen.com/books/trends-in-immunolabelled-and-related-techniques. Accessed April 20, 2016.
- Evaluation of Viva-E drug testing system.Korean J Lab Med. 2007; 27 ([in Korean]): 330-337
- Implementation of liquid chromatography/mass spectrometry into the clinical laboratory.Clin Chim Acta. 2013; 420: 4-10
- Human anti-animal antibody interferences in immunological assays.Clin Chem. 1999; 45: 942-956
- LC-MS/MS in the routine clinical laboratory: has its time come?.Anal Bioanal Chem. 2014; 406: 2289-2301
- Specificity assessment of immunoassay kits for determination of urinary free cortisol concentrations.Clin Chim Acta. 2007; 378: 66-70
- Limitations of steroid determination by direct immunoassay.Clin Chem. 2002; 48: 583-585
- Preliminary evaluation of the Abbott TDx for screening of D-methamphetamine in whole blood specimens.J Anal Toxicol. 1992; 16: 115-118
- Gas chromatography and mass spectrometry in clinical chemistry. Encyclopedia of analytical chemistry.John Wiley & Sons, Ltd, Hoboken (NJ)2006
- Gas-liquid chromatography: the separation and identification of the methyl esters of saturated and unsaturated acids from formic acid to n-octadecanoic acid.Biochem J. 1956; 63: 144-152
- Systematic toxicological analysis of drugs and their metabolites by gas chromatography-mass spectrometry.J Chromatogr. 1992; 580: 3-41
- Systematic toxicological analysis procedures for acidic drugs and/or metabolites relevant to clinical and forensic toxicology and/or doping control.J Chromatogr B Biomed Sci Appl. 1999; 733: 3-25
- Studies on the metabolism and toxicological detection of the amphetamine-like anorectic fenproporex in human urine by gas chromatography-mass spectrometry and fluorescence polarization immunoassay.J Chromatogr B Biomed Sci Appl. 2000; 738: 107-118
- Role of gas chromatography-mass spectrometry with negative ion chemical ionization in clinical and forensic toxicology, doping control, and biomonitoring.Ther Drug Monit. 2002; 24: 247-254
- Benzodiazepine analysis by negative chemical ionization gas chromatography/mass spectrometry.J Anal Toxicol. 1993; 17: 342-347
- Position of chromatographic techniques in screening for detection of drugs or poisons in clinical and forensic toxicology and/or doping control.Clin Chem Lab Med. 2004; 42: 1310-1324
- Simultaneous screening and detection of drugs in small blood samples and bloodstains.Forensic Sci Int. 2002; 126: 191-196
- Automated solid-phase extraction and two-step derivatisation for simultaneous analysis of basic illicit drugs in serum by GC/MS.Int J Legal Med. 2000; 113: 229-235
- Fully-automated systematic toxicological analysis of drugs, poisons, and metabolites in whole blood, urine, and plasma by gas chromatography-full scan mass spectrometry.J Chromatogr B Biomed Sci Appl. 1998; 713: 265-279
- Multiresidue determination method for organophosphorus pesticides in serum and whole blood by gas chromatography-mass-selective detection.J Chromatogr B Biomed Sci Appl. 2001; 759: 109-116
- Sensitive and specific multiresidue methods for the determination of pesticides of various classes in clinical and forensic toxicology.Forensic Sci Int. 2001; 121: 116-125
- Mass spectral and GC data of drugs, poisons, and their metabolites.3rd edition. Wiley-VCH, Deerfield Beach (FL)1985
- Identification and management of chronic pain in primary care: a review.Curr Psychiatry Rep. 2016; 18: 22
- Estimates of pain prevalence and severity in adults: United States, 2012.J Pain. 2015; 16: 769-780
- Pain medicine: the case for an independent medical specialty and training programs.Acad Med. 2014; 89: 863-868
- The economic costs of pain in the United States.J Pain. 2012; 13: 715-724
- Therapeutic drug monitoring of psychotropic medications.Br J Clin Pharmacol. 2001; 52: 45S-54S
- Therapeutic drug monitoring of psychotropic medications.Br J Clin Pharmacol. 2000; 49: 303-312
- A spectrum of views on clinical mass spectrometry.Clin Chem. 2016; 62: 30-36
- Quantitative performance of a quadrupole-orbitrap-MS in targeted LC–MS determinations of small molecules.J Pharm Biomed Anal. 2016; 124: 48-56
- Comparison of the quantitative performance of a Q-Exactive high-resolution mass spectrometer with that of a triple quadrupole tandem mass spectrometer for the analysis of illicit drugs in wastewater.Rapid Commun Mass Spectrom. 2013; 27: 1751-1762
- Comparative study of low- versus high-resolution liquid chromatography-mass spectrometric strategies for measuring perfluorinated contaminants in fish.Food Addit Contam Part A. 2011; 28: 1261-1273
- Large-molecule quantification: sensitivity and selectivity head-to-head comparison of triple quadrupole with Q-TOF.Bioanalysis. 2013; 5: 1181-1193
- Ambient ionization mass spectrometry for point-of-care diagnostics and other clinical measurements.Clin Chem. 2016; 62: 99-110